Siemens Digital Industries Software has released Siemens NX 2312 Build 4000 (NX 2312 Series). With each new release of NX, we’re continuing to innovate, pushing the barriers of what product development systems can do. Being on continuous release gives you access to industry-leading capabilities, helping you to maximize productivity and innovate more quickly than ever before.
NX reference-only components in Teamcenter
The reference-only design components that are used to create a model in NX are now visible in Teamcenter. When you have an NX assembly that contains a reference-only component, a Teamcenter relation is now created for the component when you use the Save, Save As, and Import Assembly into Teamcenter commands on the assembly. You can identify a reference-only component by the symbol alongside it in the Assembly Navigator.
In Active Workspace, the reference-only component is shown on the NX Properties tab in the Incoming Relations group for the assembly. It is not displayed in the list of components for the assembly in the Results panel as it is not a BOM item for the assembly.
In the Relations tab for the assembly, you can click Legend and select the new Reference Only Component color in the Relations section to show the reference-only component relationship.
In Teamcenter Structure Manager, you can view the reference-only component in the new Reference Only Component column. The reference-only component is shown as a reference to a BOM line but is not part of the structure of the assembly.
You can also view the reference-only component in the Relation Browser tab for the part in the Teamcenter rich client.
On the Impact Analysis tab in the Teamcenter rich client, for the Relation:Reference Only selection on the Where Referenced sub-tab, the component revision shows that the parent assembly has a relation to the reference-only component.
Why should I use it?
You can now identify and consider reference-only components when you work with assemblies in Teamcenter.
Filtering by attributes in an NX workset
You can now use attributes as filter criteria in a filter recipe for a workset. You can select an attribute that currently exists in the product to use in the filter recipe for a workset in NX. This is similar to attribute filtering in Active Workspace. The Attributes option is added in the Filter Type list in the Filter Recipe dialog box along with the existing Proximity, Volume, and Partition options. When you select Attributes, all the attributes that are available for the product in the workset are listed in the Attributes group.
In the Filter List group, when you click a recipe term in the Term column that contains attributes, the attributes that are available are visible in the Attributes group. The attributes are listed in the same order as they are in the Filter panel in Active Workspace. You can expand an attribute to display values for that attribute below it, such as different item types under the Type attribute.
If the list of values that is available for an attribute is extensive, you can click …More at the bottom of the list to expand it. When you select a check box to select the value, it is appended to the Filter List. To search or filter through all the available attributes, in the Filter Recipe dialog box click Filter to display the Filter dialog box. The result of the filtering is displayed in the Attributes group. You can select Contains and type a partial name to get a matching list of attributes.
Click Clear Filter in the Filter Recipe dialog box to disregard filtering that is applied and show all of the available attributes again. You can further filter an attribute by value by selecting the attribute in the Attributes group and entering a value in the filter row at the top of the value listing. You can right-click on the filter value and select Clear to remove the filter results.
Date Modified
In the Attributes group, for a date attribute, such as Date Released, select the top value and then proceed down hierarchically to the month, date range, or specific date that you want to use as a filter. When you select a check box to select the value, the date selection is appended to the Filter List group.
The reference-only design components that are used to create a model in NX are now visible in Teamcenter. When you have an NX assembly that contains a reference-only component, a Teamcenter relation is now created for the component when you use the Save, Save As, and Import Assembly into Teamcenter commands on the assembly. You can identify a reference-only component by the symbol alongside it in the Assembly Navigator.
In Active Workspace, the reference-only component is shown on the NX Properties tab in the Incoming Relations group for the assembly. It is not displayed in the list of components for the assembly in the Results panel as it is not a BOM item for the assembly.
In the Relations tab for the assembly, you can click Legend and select the new Reference Only Component color in the Relations section to show the reference-only component relationship.
In Teamcenter Structure Manager, you can view the reference-only component in the new Reference Only Component column. The reference-only component is shown as a reference to a BOM line but is not part of the structure of the assembly.
You can also view the reference-only component in the Relation Browser tab for the part in the Teamcenter rich client.
On the Impact Analysis tab in the Teamcenter rich client, for the Relation:Reference Only selection on the Where Referenced sub-tab, the component revision shows that the parent assembly has a relation to the reference-only component.
Why should I use it?
You can now identify and consider reference-only components when you work with assemblies in Teamcenter.
Filtering by attributes in an NX workset
You can now use attributes as filter criteria in a filter recipe for a workset. You can select an attribute that currently exists in the product to use in the filter recipe for a workset in NX. This is similar to attribute filtering in Active Workspace. The Attributes option is added in the Filter Type list in the Filter Recipe dialog box along with the existing Proximity, Volume, and Partition options. When you select Attributes, all the attributes that are available for the product in the workset are listed in the Attributes group.
In the Filter List group, when you click a recipe term in the Term column that contains attributes, the attributes that are available are visible in the Attributes group. The attributes are listed in the same order as they are in the Filter panel in Active Workspace. You can expand an attribute to display values for that attribute below it, such as different item types under the Type attribute.
If the list of values that is available for an attribute is extensive, you can click …More at the bottom of the list to expand it. When you select a check box to select the value, it is appended to the Filter List. To search or filter through all the available attributes, in the Filter Recipe dialog box click Filter to display the Filter dialog box. The result of the filtering is displayed in the Attributes group. You can select Contains and type a partial name to get a matching list of attributes.
Click Clear Filter in the Filter Recipe dialog box to disregard filtering that is applied and show all of the available attributes again. You can further filter an attribute by value by selecting the attribute in the Attributes group and entering a value in the filter row at the top of the value listing. You can right-click on the filter value and select Clear to remove the filter results.
Date Modified
In the Attributes group, for a date attribute, such as Date Released, select the top value and then proceed down hierarchically to the month, date range, or specific date that you want to use as a filter. When you select a check box to select the value, the date selection is appended to the Filter List group.
Release Call ID Description Application Function Sub Function
2312,4000 10702733 Joints change the position without permission KDA NX_DIAGRAMMING DESIGN
2312,4000 10729663 CAM: Toolpath Generation gives Unexpected Approach Motion CAM SURFACE_CONTOUR NON_CUT_MOVES
2312,4000 10761262 Lost basic structure attributes when update hull forms SHIP_DESIGN BASIC_DESIGN HULL
2312,4000 10785904 copy/paste disappear in CAM operation CAM USER_INTERFACE CAM_SESSION
2312,4000 10811839 Cannot copy/paste or drag and drop manufacturing objects CAM USER_INTERFACE CAM_SESSION
2312,4000 10819219 Missing Copy when Select Object in the ONT CAM USER_INTERFACE CAM_SESSION
2312,4000 10834263 SaveAs of CADItem Revision from NX is not creating DirectModel under UGALTREP as NXMANAGER FILE_SAVE_AS NEW_ITEM
2312,4000 10836903 STEP AP242: wrong PMI leader head location TRANSLATOR STEP_AP242 UG_TO_STEP
2312,4000 10847992 Unable to Create Idealized Part from Managed NX CAE ADV_SIMULATION FILE_OPERATIONS
2312,4000 10849007 Mesh associated data beams CAE ADV_SIMULATION BEAM_SECTIONS
2312,4000 10860330 Change Background - Memory Access Violation SYSENG VISUALIZATION RAYTRACESTUDIO
2312,4000 10861350 Title block not exported in DXF/DWG TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10865846 NX Item Type not finding Idealized Geometry Type CAE ADV_SIMULATION FILE_OPERATIONS
2312,4000 10865969 Assign statement is not writing properly CAE ADV_SIMULATION ANSYS_EXPORT
2312,4000 10866088 User interface has changed in bad SYSENG UI_TOOLS RIBBON
2312,4000 10867119 Problem in NX2312-EAP with not having bold text headline in menus SYSENG UI_TOOLS RIBBON
2312,4000 10867558 Difference in Material CSYS transformation results between Post and MSC Nastran CAE ADV_SIMULATION POST_RESULT
2312,4000 10867836 NX11femNX2306MAT1MAT4 CAE ADV_SIMULATION MATERIALS
2312,4000 10871561 DWG/DFX does not export title block TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10872855 1D Element-Nodal results in Post View CAE ADV_SIMULATION POST_RESULT
2312,4000 10874843 Manufacturing crashes to Gateway with \Encountered unexpected NULL pointer\ error CAM BASIC_FUNCTIONS UNDETERMINED
2312,4000 10880182 Unable to deform because, either deformed parents of component exist or deform bodies are promoted KDA REUSE_LIBRARY ADD_REUSE_COMP
2312,4000 10881054 Cannot copy/paste or drag and drop manufacturing objects CAM USER_INTERFACE CAM_SESSION
2312,4000 10882115 In Operation Navigator, right-clicking with the mouse does not allow copying. CAM USER_INTERFACE CAM_SESSION
2312,4000 10884056 SE430, In Operation Navigator,right-clicking with the mouse does not allow copying CAM USER_INTERFACE CAM_SESSION
2312,4000 10887900 NXD Equipment's port disappears even though it's not connected. KDA NX_DIAGRAMMING DESIGN
2312,4000 10890592 Stiffeners not limited by their boundaries when exporting to OCX SHIP_DESIGN BASIC_DESIGN STRUCTURE_XML
2312,4000 10890848 CatiaV5 translator generates a geometry (face) that has a deviation from the Catia input geometry TRANSLATOR CATIAV5 IMPORT_GEOMETRY
2312,4000 10890994 Reuse Library: Specifications don't filter correctly ROUTING_GENERAL REUSE_LIBRARY SPECIFICATIONS
2312,4000 10891077 NXD Ports in the wrong place in diagram KDA NX_DIAGRAMMING DESIGN
2312,4000 10891603 Disabling part thumbnails in dialogs customer default breaks add component function. ASSEMBLIES ASSEMBLY_MODEL CLONE_ASSEMBLY
2312,4000 10891828 \Internal error: memory access violation\ when open a Workset from AW embedded in NXManager. NXMANAGER FILE_OPEN PARTITIONS
2312,4000 10893148 Behavior of global ID in IFC Translator ( NX 2306.5001 and NX_EAP 2312.1500 ) TRANSLATOR IFC EXPORT
2312,4000 10893895 In NX2306 when creating an associative measure, fix at current timestamp is no longer on by default DESIGN INFO_ANALYSIS MEASURE
2312,4000 10895142 Unable to connect to Two Ports in the same position KDA NX_DIAGRAMMING DESIGN
2312,4000 10895200 Junctions are moved when inserting inline equipment KDA NX_DIAGRAMMING DESIGN
2312,4000 10895900 DTP_LD_Copy and Paste duplicate is not working for Resource in NX Line Designer MFG_LINE_DESIG GENERAL ALL
2312,4000 10896213 Mechanical Load Summary retrieves different results between SC3D 2306 and SC3D 2206 CAE ADV_SIMULATION CHK_LOAD_CNTRS
2312,4000 10897010 Severe errror when updating views in Drafting SHIP_DESIGN DRAFTING SHIP_SECTN_DRWG
2312,4000 10897999 Using custom Reuse Library from network share now incredibly slows down NX GUI KDA REUSE_LIBRARY LIBRARY_MGT
2312,4000 10899140 Linked bodies in assembly at wrong position in QGDC7X9999212 CORRUPTED_PARTS MODELING ALL
2312,4000 10899147 Linked bodies in assembly with wrong size in QGDC7X9999212 CORRUPTED_PARTS MODELING ALL
2312,4000 10899618 A-Pillar feature cannot be opened after save KDA GENERAL_PACKAGE APILLAR_OBSCURE
2312,4000 10901739 Tooling BOM Export to Spreadsheet fails with invalid path in Native_BOM_Location attribute KDA MOLDWIZARD BOM
2312,4000 10905155 Text from a symbol appear out of the symbol whe flip or rotate de symbol. KDA NX_DIAGRAMMING DESIGN
2312,4000 10907785 Different font used in the NX menus SYSENG UI_TOOLS RIBBON
2312,4000 10908633 Error message displayed when measure a projection distance. DESIGN INFO_ANALYSIS MEASURE
2312,4000 10909078 Missing pythonStubs folder to support NXOpen Python Intellisense in NX2312 SYSENG NXOPEN PYTHON
2312,4000 10911056 C++ Exception using WAVE Geometry Linker ASSEMBLIES ASSEMBLY_MODEL CLONE_ASSEMBLY
2312,4000 10912908 Missing bold fonts in File sub-menus SYSENG UI_TOOLS RIBBON
2312,4000 10915297 Missing Title Block after export TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10931339 Tooling BOM UI closes immediately when applying any Column Filter KDA MOLDWIZARD BOM
2312,4000 10934110 Mold Wizard BOM Export to Excel does not perform any action KDA MOLDWIZARD BOM
2312,4000 10939976 NX2312: Under File Utilities different font to NX2206 SYSENG UI_TOOLS RIBBON
2312,4000 12002929 Mechanical Load Summary retrieves diferent results between SC3D 2306 and SC3D 2206 CAE ADV_SIMULATION CHK_LOAD_CNTRS
2312,4000 10702733 Joints change the position without permission KDA NX_DIAGRAMMING DESIGN
2312,4000 10729663 CAM: Toolpath Generation gives Unexpected Approach Motion CAM SURFACE_CONTOUR NON_CUT_MOVES
2312,4000 10761262 Lost basic structure attributes when update hull forms SHIP_DESIGN BASIC_DESIGN HULL
2312,4000 10785904 copy/paste disappear in CAM operation CAM USER_INTERFACE CAM_SESSION
2312,4000 10811839 Cannot copy/paste or drag and drop manufacturing objects CAM USER_INTERFACE CAM_SESSION
2312,4000 10819219 Missing Copy when Select Object in the ONT CAM USER_INTERFACE CAM_SESSION
2312,4000 10834263 SaveAs of CADItem Revision from NX is not creating DirectModel under UGALTREP as NXMANAGER FILE_SAVE_AS NEW_ITEM
2312,4000 10836903 STEP AP242: wrong PMI leader head location TRANSLATOR STEP_AP242 UG_TO_STEP
2312,4000 10847992 Unable to Create Idealized Part from Managed NX CAE ADV_SIMULATION FILE_OPERATIONS
2312,4000 10849007 Mesh associated data beams CAE ADV_SIMULATION BEAM_SECTIONS
2312,4000 10860330 Change Background - Memory Access Violation SYSENG VISUALIZATION RAYTRACESTUDIO
2312,4000 10861350 Title block not exported in DXF/DWG TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10865846 NX Item Type not finding Idealized Geometry Type CAE ADV_SIMULATION FILE_OPERATIONS
2312,4000 10865969 Assign statement is not writing properly CAE ADV_SIMULATION ANSYS_EXPORT
2312,4000 10866088 User interface has changed in bad SYSENG UI_TOOLS RIBBON
2312,4000 10867119 Problem in NX2312-EAP with not having bold text headline in menus SYSENG UI_TOOLS RIBBON
2312,4000 10867558 Difference in Material CSYS transformation results between Post and MSC Nastran CAE ADV_SIMULATION POST_RESULT
2312,4000 10867836 NX11femNX2306MAT1MAT4 CAE ADV_SIMULATION MATERIALS
2312,4000 10871561 DWG/DFX does not export title block TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10872855 1D Element-Nodal results in Post View CAE ADV_SIMULATION POST_RESULT
2312,4000 10874843 Manufacturing crashes to Gateway with \Encountered unexpected NULL pointer\ error CAM BASIC_FUNCTIONS UNDETERMINED
2312,4000 10880182 Unable to deform because, either deformed parents of component exist or deform bodies are promoted KDA REUSE_LIBRARY ADD_REUSE_COMP
2312,4000 10881054 Cannot copy/paste or drag and drop manufacturing objects CAM USER_INTERFACE CAM_SESSION
2312,4000 10882115 In Operation Navigator, right-clicking with the mouse does not allow copying. CAM USER_INTERFACE CAM_SESSION
2312,4000 10884056 SE430, In Operation Navigator,right-clicking with the mouse does not allow copying CAM USER_INTERFACE CAM_SESSION
2312,4000 10887900 NXD Equipment's port disappears even though it's not connected. KDA NX_DIAGRAMMING DESIGN
2312,4000 10890592 Stiffeners not limited by their boundaries when exporting to OCX SHIP_DESIGN BASIC_DESIGN STRUCTURE_XML
2312,4000 10890848 CatiaV5 translator generates a geometry (face) that has a deviation from the Catia input geometry TRANSLATOR CATIAV5 IMPORT_GEOMETRY
2312,4000 10890994 Reuse Library: Specifications don't filter correctly ROUTING_GENERAL REUSE_LIBRARY SPECIFICATIONS
2312,4000 10891077 NXD Ports in the wrong place in diagram KDA NX_DIAGRAMMING DESIGN
2312,4000 10891603 Disabling part thumbnails in dialogs customer default breaks add component function. ASSEMBLIES ASSEMBLY_MODEL CLONE_ASSEMBLY
2312,4000 10891828 \Internal error: memory access violation\ when open a Workset from AW embedded in NXManager. NXMANAGER FILE_OPEN PARTITIONS
2312,4000 10893148 Behavior of global ID in IFC Translator ( NX 2306.5001 and NX_EAP 2312.1500 ) TRANSLATOR IFC EXPORT
2312,4000 10893895 In NX2306 when creating an associative measure, fix at current timestamp is no longer on by default DESIGN INFO_ANALYSIS MEASURE
2312,4000 10895142 Unable to connect to Two Ports in the same position KDA NX_DIAGRAMMING DESIGN
2312,4000 10895200 Junctions are moved when inserting inline equipment KDA NX_DIAGRAMMING DESIGN
2312,4000 10895900 DTP_LD_Copy and Paste duplicate is not working for Resource in NX Line Designer MFG_LINE_DESIG GENERAL ALL
2312,4000 10896213 Mechanical Load Summary retrieves different results between SC3D 2306 and SC3D 2206 CAE ADV_SIMULATION CHK_LOAD_CNTRS
2312,4000 10897010 Severe errror when updating views in Drafting SHIP_DESIGN DRAFTING SHIP_SECTN_DRWG
2312,4000 10897999 Using custom Reuse Library from network share now incredibly slows down NX GUI KDA REUSE_LIBRARY LIBRARY_MGT
2312,4000 10899140 Linked bodies in assembly at wrong position in QGDC7X9999212 CORRUPTED_PARTS MODELING ALL
2312,4000 10899147 Linked bodies in assembly with wrong size in QGDC7X9999212 CORRUPTED_PARTS MODELING ALL
2312,4000 10899618 A-Pillar feature cannot be opened after save KDA GENERAL_PACKAGE APILLAR_OBSCURE
2312,4000 10901739 Tooling BOM Export to Spreadsheet fails with invalid path in Native_BOM_Location attribute KDA MOLDWIZARD BOM
2312,4000 10905155 Text from a symbol appear out of the symbol whe flip or rotate de symbol. KDA NX_DIAGRAMMING DESIGN
2312,4000 10907785 Different font used in the NX menus SYSENG UI_TOOLS RIBBON
2312,4000 10908633 Error message displayed when measure a projection distance. DESIGN INFO_ANALYSIS MEASURE
2312,4000 10909078 Missing pythonStubs folder to support NXOpen Python Intellisense in NX2312 SYSENG NXOPEN PYTHON
2312,4000 10911056 C++ Exception using WAVE Geometry Linker ASSEMBLIES ASSEMBLY_MODEL CLONE_ASSEMBLY
2312,4000 10912908 Missing bold fonts in File sub-menus SYSENG UI_TOOLS RIBBON
2312,4000 10915297 Missing Title Block after export TRANSLATOR DXF_DWG EXPORT_DRAFTING
2312,4000 10931339 Tooling BOM UI closes immediately when applying any Column Filter KDA MOLDWIZARD BOM
2312,4000 10934110 Mold Wizard BOM Export to Excel does not perform any action KDA MOLDWIZARD BOM
2312,4000 10939976 NX2312: Under File Utilities different font to NX2206 SYSENG UI_TOOLS RIBBON
2312,4000 12002929 Mechanical Load Summary retrieves diferent results between SC3D 2306 and SC3D 2206 CAE ADV_SIMULATION CHK_LOAD_CNTRS
Siemens NX’s continuous release strategy is what we are providing, to bring you the latest and greatest every six months. We are striving to consistently deliver value to you and enhance productivity and user experience across Siemens NX. Innovating new technology and capabilities is only part of our arsenal. We also continue to revolutionize our existing capabilities to ensure that we provide the maximum level of efficiency and ultimate user-experience for you, our customers. Siemens is the first CAD/CAM/CAE software company to offer a continuous release model. With NX Continuous Release, upgrading is fast, automated, and seamless.
What's new in NX 2312 (December 2023 Release)
Siemens Digital Industries Software is a global leader in the growing field of product lifecycle management (PLM), manufacturing operations management (MOM), and electronic design automation (EDA) software, hardware, and services. Siemens works with more than 100,000 customers, leading the digitalization of their planning and manufacturing processes. At Siemens Digital Industries Software, we blur the boundaries between industry domains by integrating the virtual and physical, hardware and software, design and manufacturing worlds.
Owner: Siemens Digital Industries Software
Product Name: NX Continuous Release
Version: 2312 Build 4000 (NX 2312 Series)
Supported Architectures: x64
Website Home Page : www.plm.automation.siemens.com
Languages Supported: multilanguage
System Requirements: Windows *
Size: 15.2 Gb
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please