Zuken E3.series 2021 SP2 (22.20.0.0) | 4.4 Gb
Languages Supported: English, Español, 中文, Deutsch, Français, Italiano,
日本語, Nederlands, Polski, Português, Русский, Türkçe, Svenska
Languages Supported: English, Español, 中文, Deutsch, Français, Italiano,
日本語, Nederlands, Polski, Português, Русский, Türkçe, Svenska
Zuken announces the 2021 release of E3.series focusing on increasing user efficiency through extended functionality in connector handling, 3D control cabinet design and component database as well as API extensions enabling the creation of user-defined add-on programs and interfaces.
The enhancements, many of which were initiated as part of joint projects with major global E3.series customers, have been designed to make electrical and fluid engineering more intuitive and therefore faster, easier, and more robust.
Improved connector handling during schematic design
In the areas of schematic and cabling, the 2021 release introduces additional online checks for manually plugging connectors, complementing E3.series’ automatic selection of mating connectors from the database. If a connector is assigned or modified manually, the error checking functionality now looks up eligible mating connectors in the database and issues a warning if an incompatible connector has been selected. The checks also prevent the manual connection of plug-on-plug or socket-on-socket.
Another important extension in the schematics application addresses the handling of connectors with inserts, which combine several different connectors into a single complex component. These complex connectors can be defined in the E3.series database or dynamically with more control when the connector with inserts is configured in the E3.series project
Enhanced 3D cabinet and wire harness design
In E3.panel, the 2D/3D cabinet design module of E3.series, the creation of cabinet and panel models now requires significantly less effort. The 2D and 3D graphical representations are created automatically from an imported STEP file. These include the various side views from the 2D graphical representation along with the model dimensions. DXF files are no longer required.
A new highlight panel path command enables quick display of the routing path of a wire throughout the cabinet. The highlighted path is automatically displayed on all sheets and 3D views where the wire is represented. If a sheet is not open or active it is automatically opened so the user will not have to spend time searching for the required sheet. A more sophisticated control of the filling limits for cable ducts now allows a differentiated definition of the available space in the various segments of a cable duct. In this way, the automatic routing algorithm can allow for reserves for future changes or additional wires.
The output of 3D information for 3D mechanical CAD systems has been significantly enhanced by adding the JT format to the previously used STEP output. JT is a format that all commonly used MCAD systems can read. In addition to the graphical representation of cabinet or wire harness designs it also supports the export of the content of the cabinet or mounting plate, including all devices, mounting rails, cable ducts, and wires.
Database accessibility, reports and Application Programming Interface (API)
The relationships between components and symbols in the database can be displayed in an additional window to enable a quick and thorough overview. The new database relations window opens with a single click on a component in the database tree and displays all related information at one glance. This new display helps database admins understand the relationships between components and symbols in their database and manage them with ease.
E3.ReportGenerator is a new module within the standard E3.series configuration. With it, users can now create individual lists from E3.series without special programming or additional software. Via a graphical user interface, the layout and the content of reports can be created quickly and easily and the output can be generated in various formats. All lists can then be loaded into E3.series sheets along with their defined layout.
All new functions and commands in E3.series 2021 are also covered in the API that is included as part of the standard E3.series configuration. This interface offers many functions to access the existing data from an E3.series project and to modify or add new data. It is used by Zuken’s E3.series add-on programs and by customers and partners who use its functionality to exchange data with an E3.series project.
A powerful electrical engineering environment
E3.series is a true concurrent electrical engineering environment supporting advanced requirements for electrical documentation, cabinet and wire harness design, and manufacturing outputs. The tool suite facilitates an efficient and accurate design and manufacturing process for electrical and fluid planning, cable planning, and wire harness and cabinet layout. E3.series is widely used in the manufacturing industry to design large, complex electrical cabling, control cabinet, and wire harness designs for advanced applications in the machinery, power, automotive, transportation, and aerospace, and defense industries.
Designer-08591 Query when saving after a change in a model whether all components using this model should be updated, although the changes in the model are not structure-relevant for the component
Designer-39514 Settings - Connection - Cores / Wires - move core ends: Selection in pulldown menu in Japanese environment incorrect
Designer-39660 Customize "Context menu" in DBE does not work or must not be offered
Designer-39696 Transformed graphic not displayed correctly after DXF export
Designer-39723 In the tab "Pins" and "Calculation" in the component properties of a block connector, the info column does not contain the connector name.
Designer-39807 Structure blocks cannot be copied
Designer-39890 A crash may occur when editing panel models if specific text fonts are used that cannot be correctly converted as 3D fonts in 3D rendering
Designer-39984 Crash when assigning an assembly component type to a dynamic assembly where the assembly parts do not match
Designer-39991 Better performance when switching options in a project with a lot of formboard tables.
Designer-40020 Workspace configuration saved if a script in E3 crashes and E3 is closed
Designer-40031 Cables may not be merged when importing a subcircuit
Designer-40039 Columns not visible in pin table
Designer-40044 With the COM call 'GetWireHoseTubeStyle' there is no distinction if the wire color is "black" or automatic
Designer-40090 When automatically loading the end brackets of a terminal strip, the first end bracket does not take on the attributes of the structure definition
Designer-40094 Attribute texts (#1000) may disappear on the sheet after switching elements in the tree
Designer-40105 Cavity part component can be deleted even if still used in a component
Designer-40106 Used preview or table symbol can be deleted with <yes>, even though still used
Designer-40122 COM: the call 'GetConnectionIds' returns too many connections
Designer-40124 If the graphic of a mounting plate does not match the size of the mounting plate, cable ducts and mounting rails may not be displayed in the 2D view
Designer-40149 Texts on open terminal plan sheet not updated after moving end terminals in panel or device tree
Designer-40160 Message "I - Region not changed because it differs from database definition" in DBE although the region is identical
Designer-40163 COM: Text.CalculateBoxHeight() returns different values depending on line breaks
Designer-40164 Error message when moving block in tree (if device table is active)
Designer-40165 Performance improvement while connecting in large E3.topology nets.
Designer-40166 DBE - Not possible to create multiple numeric bus pins with same name without closing pin assignment dialog after each change made
Designer-40189 Switch cabinet - Faulty Fill grade calculation in specific cases
Designer-40191 Wire color 0 cannot be assigned
Designer-40195 Import subcircuit: Cores with the same name and with options / variants are renamed during import
Designer-40200 E3.ReportScripts: Table of Contents - Non-translatable texts, date edited and editor missing in output on sheet since version 2021-22.1
Designer-40203 Item validation may prevent import of a sub-circuit
Designer-40224 Defined highlight color does not work for wire connections in control cabinet/panel
Designer-40336 No ascending/descending sorting in device tree for devices in dynamic assemblies does not work
Additionally to the bug fixes we also have added some new / enhanced functionality in this Patch
Designer-39943 COM: New call "Sym.MoveInteractively"/ enhanced Call "Sym.PlaceInteractively" with which an already placed symbol is moved to the cursor and can be placed interactively
Designer-39514 Settings - Connection - Cores / Wires - move core ends: Selection in pulldown menu in Japanese environment incorrect
Designer-39660 Customize "Context menu" in DBE does not work or must not be offered
Designer-39696 Transformed graphic not displayed correctly after DXF export
Designer-39723 In the tab "Pins" and "Calculation" in the component properties of a block connector, the info column does not contain the connector name.
Designer-39807 Structure blocks cannot be copied
Designer-39890 A crash may occur when editing panel models if specific text fonts are used that cannot be correctly converted as 3D fonts in 3D rendering
Designer-39984 Crash when assigning an assembly component type to a dynamic assembly where the assembly parts do not match
Designer-39991 Better performance when switching options in a project with a lot of formboard tables.
Designer-40020 Workspace configuration saved if a script in E3 crashes and E3 is closed
Designer-40031 Cables may not be merged when importing a subcircuit
Designer-40039 Columns not visible in pin table
Designer-40044 With the COM call 'GetWireHoseTubeStyle' there is no distinction if the wire color is "black" or automatic
Designer-40090 When automatically loading the end brackets of a terminal strip, the first end bracket does not take on the attributes of the structure definition
Designer-40094 Attribute texts (#1000) may disappear on the sheet after switching elements in the tree
Designer-40105 Cavity part component can be deleted even if still used in a component
Designer-40106 Used preview or table symbol can be deleted with <yes>, even though still used
Designer-40122 COM: the call 'GetConnectionIds' returns too many connections
Designer-40124 If the graphic of a mounting plate does not match the size of the mounting plate, cable ducts and mounting rails may not be displayed in the 2D view
Designer-40149 Texts on open terminal plan sheet not updated after moving end terminals in panel or device tree
Designer-40160 Message "I - Region not changed because it differs from database definition" in DBE although the region is identical
Designer-40163 COM: Text.CalculateBoxHeight() returns different values depending on line breaks
Designer-40164 Error message when moving block in tree (if device table is active)
Designer-40165 Performance improvement while connecting in large E3.topology nets.
Designer-40166 DBE - Not possible to create multiple numeric bus pins with same name without closing pin assignment dialog after each change made
Designer-40189 Switch cabinet - Faulty Fill grade calculation in specific cases
Designer-40191 Wire color 0 cannot be assigned
Designer-40195 Import subcircuit: Cores with the same name and with options / variants are renamed during import
Designer-40200 E3.ReportScripts: Table of Contents - Non-translatable texts, date edited and editor missing in output on sheet since version 2021-22.1
Designer-40203 Item validation may prevent import of a sub-circuit
Designer-40224 Defined highlight color does not work for wire connections in control cabinet/panel
Designer-40336 No ascending/descending sorting in device tree for devices in dynamic assemblies does not work
Additionally to the bug fixes we also have added some new / enhanced functionality in this Patch
Designer-39943 COM: New call "Sym.MoveInteractively"/ enhanced Call "Sym.PlaceInteractively" with which an already placed symbol is moved to the cursor and can be placed interactively
E³.series is a complete and open CAD solution for design and documentation of electrical and automation systems. It also includes integrated logic-orientated functionality for the creation of cabling and harnesses. E³.series is based upon common component databases and symbol libraries and ensures a unique representation of all elements of the circuit diagrams, to produce accurate and error-free documentation. It also allows for creation of block diagrams, under logic control, that provide an overview of all electrical and electronic elements. Connections between functional modules can be achieved using individual cores, shielded or twisted cables or bundled cables.
Zuken E3.Series Workspace Tip
Quick Video Highlighting how to save your work
Zuken is a global software company delivering electrical and electronic design solutions. Founded in 1976, Zuken has a consistent track record of technology innovation and financial stability in the electronic and electrical design automation (EDA) industry. With its CR-8000 and E3.series product families, Zuken provides a robust lineup of system-level 2D/3D electrical and electronic toolsets complemented by comprehensive design data and configuration management capabilities.
Product: Zuken E³.series
Version: 2021 SP2 (22.20.0.0)
Supported Architectures: x64
Website Home Page : www.zuken.com
Languages Supported: multilanguage
System Requirements: Windows *
Size: 4.4 Gb
Please visit my blog
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please
Added by 3% of the overall size of the archive of information for the restoration
No mirrors please