Tags
Language
Tags
November 2024
Su Mo Tu We Th Fr Sa
27 28 29 30 31 1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30

BETA-CAE Systems 22.1.3

Posted By: scutter
BETA-CAE Systems 22.1.3

BETA-CAE Systems 22.1.3 | 2.2 Gb

BETA CAE Systems announces the release of 22.1.3. The deployment of 22.1.3 will maximize the performance and enhance the daily practices of those who already enjoy the benefits of the previous releases of this version, but especially of those who have not yet migrated to 22.x.

Known issues resolved in ANSA

CAD Import/ Export
- CAD to ANSA parallel translation would not release translation credits upon translation completion.
- Multi-instantiated parts with different CAD references would be erroneously positioned and potentially existing double dollars '$ $' in the filename would be erroneously translated into single dollar '$'.
- Furthermore, regarding Product Tree Editor and especially CAD to ANSA functionality, the Vismockup plmxml parser has been enhanced to read the Part Names from ProductInstance, when no ProductRevisionView is defined.
GUI
- The pull-down menus of some Module Buttons might not be visible when placed in a custom menu if the GUI Settings *.xml file has been created before v22.0.0.
- Moreover, when double-clicking on User Attributes Lists in Settings, unexpected termination would occur.
Data Management
- Referring to DM Cluster functionality, when executing "Send to DM" process more than once, despite the successfull transfer between the source and the local DM, ANSA would erroneously cease the "Send to DM" process due to Source and Target DM incompatibility.
- The number of displayed results under base.OpenDMObjectsInNewTab() would be falsely limited to 1000.
Modular Run Management
- ANSA would unexpectedly terminate upon displaying the "Interface Node->MBContainer" column in the INTERFACE POINTS list in Database Browser.
Connections & Assembly
- Projection Method on RBE3 – HEXA – RBE3 would result in misplaced RBE3s, when the connectivity entries of Adhesive Lines were on the same Part.
Shell Mesh
- Running the script function mesh.ReconstructShells() would occasionally lead to unexpected termination, due to corrupted tria shells with common nodes in wrong positions.
DECKs
- Occasionally, when opening (via File > Input) large files of whole vehicle models containing approx. 5 to 10 million elements and 500 to1000 MB in size, the Database Browser update would require more time than expected.
Report
- In Deck Report and Deck Info, requesting "Batch mesh statistics" for multiple scenarios, would fail.
- For LS-DYNA models, scaled mass would be erroneously calculated, in case MAREA mass existed in the model.
- Moreover, in Radioss, TOTAL MASS would be erroneously calculated after a Subsystems DM> Change Representation of Lumped Mass.

Known issues resolved in META

General
- META would unexpectedly terminate, when launcher.txt file had a reference to an *.xml file that didn't exist.
Read Results
- When reading LS-DYNA results, the Integration Points order for tetrahedron elements and the mean pressure result would not be read properly.
- Also, Radioss USER VAR 5 results were occasionally not read correctly.
Managing Curve Data
- Curves of AnimatorDB couldn't be plotted, when an Animator database was read like a common 2d-time history file.
NVH Calculators
- The numerical accuracy for transient response analysis has been improved for cases where rigid body modes contribute to the response.
Report
- Adding an *.xlsm file in the Report Composer would produce an error, when saving the report as a *.pptx file.
File Export
- Unexpected termination could occur while generating preview of the exported CSV Results file.
CompositePost Toolbar
- The execution of Plot results 2D vs. Thickness command would lead to unexpected termination, when unavailable results were requested under Plot results 2D > Options. To overcome this, a check has been added and unavailable results are now skipped.

New Documentation in KOMVOS

Best Practices
- Machine Learning in feature detection – Embedded clips handling

BETA-CAE Systems 22.1.3

BETA-CAE Systems 22.1.3

BETA-CAE Systems 22.1.3

The engineers at BETA CAE Systems see simulation as a tool that can be used to predict the future. The Swiss company seeks to offer tools for every stage of the product development process, and its vision is to stop trade-off thinking. Instead of working under the constraints of quality, time and cost, the company hopes that customers using its tools early enough in the process will be able to win in all three areas.

Working through a full development cycle can require different tools for different phases. ANSA is the preprocessor tool that accepts CATIA V4, CATIA V5, NX, Pro/ENGINEER and Jupiter Tessellation (JT) files. The EPILYSIS solver performs structured analysis in both linear and nonlinear paths. The META post-processor offers several options for framing and presenting a study, with a focus on graphics and visualization.

The new version 22.0.0 of the BETA CAE systems software suite comes with numerous new tools and features, designed to facilitate and expand your simulation processes.

ANSA v22.0.0 highlights


BETA is a simulation solutions provider, dedicated to the development of state of the art software systems. For almost 30 years, BETA has been developing tools and delivering services for the front runners of numerous sectors by listening to their needs and taking up even the most demanding challenges.

Product: BETA CAE Systems
Version: 22.1.3
Supported Architectures: x64
Website Home Page : www.beta-cae.com
Languages Supported: english
System Requirements: Windows *
Size: 2.2 Gb

BETA-CAE Systems 22.1.3

Compatibility and Supported Platforms

ANSA files saved by all the first and second point releases of a major version are compatible to each other. New major versions can read files saved by previous ones but not vice versa.

META Project files saved from version 22.1.3 are compatible and can be opened by META version 16.0.0 or later.

Support for Mac OS has been discontinued.

Support for 32-bit platforms has been discontinued for all operating systems.

Please visit my blog

Added by 3% of the overall size of the archive of information for the restoration

No mirrors please


BETA-CAE Systems 22.1.3